{"id":82,"date":"2007-08-25T16:20:56","date_gmt":"2007-08-25T20:20:56","guid":{"rendered":"http:\/\/gwapa.org\/wordpress\/?page_id=82"},"modified":"2008-09-06T16:22:19","modified_gmt":"2008-09-06T20:22:19","slug":"multi-tank-setups-with-planted-tanks-pros-cons","status":"publish","type":"page","link":"https:\/\/gwapa.org\/wordpress\/articles\/multi-tank-setups-with-planted-tanks-pros-cons\/","title":{"rendered":"Multi-tank Setups with Planted Tanks &#8211; Pros &#038; Cons"},"content":{"rendered":"<p><em>At the August 2007 meeting, Robert T. Ricketts talked about the pros          and cons of running planted tanks in a multi-tank system. Robert has written          up his talk in his notes below&#8230;<\/em><\/p>\n<p><img decoding=\"async\" src=\"http:\/\/gwapa.org\/articles\/august2007\/images\/4.jpg\" alt=\"\" \/><\/p>\n<p>In principle these systems are doing the same job as the use of a sump          on a display tank to house some, most, or all of the required jobs of          operation (heating, filtration, circulation), just expanded to serve more          than one tank. The complexity of the plumbing is the primary difference          from such tank-with-sump practice.<\/p>\n<p>\u00e2\u20ac\u0153Central systems\u00e2\u20ac\u009d in current practice have central setups          involving reservoirs or sumps from which processed water is distributed          to each tank directly with metering valves to control the flow to each          tank from the pressurized manifold (#1). That is comparable to the more          familiar situation in which we use gang valves to distribute air from          one pump to multiple air-operated devices, each with its own demand for          flow, or in the same manner as a pressurized CO2 manifold feeding multiple          tanks from a single pressure bottle. A central system functions essentially          in the same manner for water. Each tank has over-the-side overflow or          drilled bulkhead return(s) directly to a generally un-pressurized (gravity)          return manifold draining to the central processing unit (#2). The return          sump may use a separate pump to move water from the return sump to or          through various devices, most often filters, or may use gravity flow to          accomplish this. Individual tanks do not need to have their own biological          or mechanical filters, but may have such if desired. Such systems commonly          use constant-level siphons to maintain tank water levels if the tanks          are not drilled for overflow. The central system technique is the newer          of the two, as useful and practically priced valves and hobbyist-friendly          piping were not readily available when the first multi-tank systems were          developed.<\/p>\n<p>\u00e2\u20ac\u0153Circulating ranges\u00e2\u20ac\u009d have similar central processing units,          but processed water is fed to the first tank in a series, with flow-through          to the next and subsequent tanks in the series throughout the range. This          sequential flow contrasts with the basically parallel flow in central          systems. IME, circulating ranges operate best with each tank in the series          having at least minimal mechanical and biological filtration of its own.          Unit flow through the individual tanks need not be as great and is generally          lower than with most central systems, but may be comparable to such systems.          My current circulating range involves two separate loops. Level changes          in such systems again require constant-level siphons. Hard-plumbed connections          between tanks are not the best choice here, as the rigidity of such couplings          is a risk. Simple siphons are in the long run more controllable.<\/p>\n<p>The two major benefits of such setups are consistency of water parameters          tank-to-tank, and ease of operation in water partials (which may be automated),          and parameter testing. The major disadvantage is the absolute requirement          for healthy stock throughout the system \u00e2\u20ac\u201c one communicably diseased          fish added to the system, or one plant (or any other material) from a          diseased setup could introduce problems via attached parasites or coating          water which would be spread throughout the system. Rigorous quarantine          is an absolute requirement. Another major disadvantage particularly for          planted tank folk is that such setups are quite unfriendly to elevated          dissolved CO2 levels as they generally involve open-to-the-atmosphere          return plumbing which is well able to blow off elevated dissolved CO2          down to air-exchange levels (2-5 ppm CO2, #3). Many systems involve processed          water returns to the tanks involving surface agitation to promote high          oxygenation levels, and may also involve open-to-the-air filtration processes.<\/p>\n<p>All such systems need some redundancy for operational safety. Most often          this involves duplicated returns as these are the most likely trouble          spots due to clogging (#4), but duplicated feeds may also be used in the          most cautiously constructed setups.<\/p>\n<p>If local water supplies do not provide the appropriate water type for          the critters being kept, modifications are best done before adding water          to the system. But that is no different from best practice for individual          tanks. In-tank water modification is always a non-trivial risk to me.          Also for me, handling of utility-added water treatments (#5) are also          best done before the water is added to the system.<\/p>\n<p>The reduced requirement for biological filtration seen in single healthy          planted tanks is unchanged in such systems, logically enough. The requirement          for mechanical filtration is in no way reduced \u00e2\u20ac\u201c in circulating          ranges it is, if anything, increased. That increase is needed to insure          that the downstream tanks in a series do not become settling tanks for          the prior tanks in the system, and thereby require extra vacuuming and          other upkeep if not carefully mechanically filtered. Additionally, circulating          ranges and some central systems lack sufficient flow to provide sufficient          current in the individual tanks. As long as you are using power to move          water anyway, you might as well get more bang for the buck by using filtration          at the same time. As I separate mechanical and biological filtration as          much as possible in all my tanks and use mechanical filters as current          providers, this is easily done for me. Mechanical filters (entirely sponges          for me) can be tap rinsed frequently (#6) with no special care. Even return          of particular sponges to the same tank or filter is trivial \u00e2\u20ac\u201c cross-contamination          is hardly an issue, everything in the system is exposed to everything          else in any case.<\/p>\n<p>Such systems do not for me operate untended for extended periods, as          individual fully self-contained tanks can do. Such systems absolutely          need routine checks for circulation (both to all tanks and within each          tank), water levels throughout the system, evaporation make-up (if not          automated \u00e2\u20ac\u201c which subsystem would still require checking), temperature,          etc. at least every other day and best daily. With such systems, floods          are always more possible than with single-tank setups. That is the biggest          factor and argument for redundancy in equipment and fittings.<\/p>\n<p>Individual tank care is much like that of any tank. Vacuuming is routine,          and if done with any care does not cloud the system. Major tank overhauls          are, if anything, easier than in single tanks as any temporary setback          (#7) is readily compensated for by the rest of the system. The margin          of biological safety is massive by comparison to a single tank. Stocking          changes in any given tank are trivial (#8). Bioload is balanced throughout          the system.<\/p>\n<p>Individual tank vacuuming, even a major overhaul, is done with care only          that you do not take the central sump\/overflow levels too low for normal          operation. In central systems, individual tanks may be isolated from the          system if desired for such work. In circulating ranges that is harder          (but possible) and I usually do not do so, but in extreme cases (replacing          a leaking tank) I do bridge between tanks. You just monitor the water          levels in the tank in single tanks. In interconnected systems you work          on one tank and watch the system sump.<\/p>\n<p>The most common risk is not allowing for sufficient drain-down margin          in power-off situations (#9). Without sufficient drain-down area and volume,          you have a guaranteed flood. Systems must be tested not just for function,          but for malfunction as well.<\/p>\n<p>There are a couple of frequently used water partial techniques. While          doing routine light vacuuming, I normally add make-up water relatively          slowly by a lower-flow pump to the sump\/overflow to compensate for the          water I am removing. For faster partials without vacuuming in my circulating          range, I shut down the circulation of the system, leaving the internal          circulation (mechanical and biofiltration) of the individual tanks operating.          I remove water from the system sump, adding new water by a higher-flow          pump to the first tank in the system. As my maximum replaced water in          one partial is about one-third of system total volume, not too much \u00e2\u20ac\u0153new\u00e2\u20ac\u009d          water is lost due to the constant withdrawal\/addition during the partial          change. That technique is the more effective of the two for the water          itself. In a single tank, that technique would not be as effective, there          would be too much new water removed by constant mixing.<\/p>\n<p>Such systems as these are not new. My first awareness of such came from          a Pet Library volume by Dr. Ferose N. Ghadially, the Advanced Aquarist          Guide, 1969. Coupled with the circulating range concept was the idea of          constant-level siphons, which are generally needed in such a system. By          his references in that book, such practices were used back to the early          1950s. Being a lab person and a bit of a gadget nut, I had to try one.          It worked beautifully. My now 37-year old son was a bit past toddler stage          at the time I first saw the book. It incorporated veggie filters and a          24\/7-lighted daphnia refugium both of which also have been used in my          current setup. That same book first detailed Monaco-style tanks for me.          We have better tools now, but still use them to accomplish the same ends.<\/p>\n<p><strong>Footnotes:<\/strong><\/p>\n<p>#1: These delivery pipes may recirculate as a loop, or may be dead-end.          The former is preferred due to improved oxygenation and consistent mixing.          Bleeding off water back into the source sump maintains line pressure but          avoids the stagnation of a dead-end setup.<\/p>\n<p>#2: Please do not attempt to \u00e2\u20ac\u0153balance\u00e2\u20ac\u009d pumps \u00e2\u20ac\u201c i.e.,          having one pumping water into a tank, and another pumping water out of          the tank. It does not work.<\/p>\n<p>#3: The 2-5ppm data from George Booth is for well-aerated water without          significant metabolic activity. Well-established tanks with livestock          and non-trivial tank, filter, and substrate bacterial activity will show          levels higher than clean-water equilibrium if not strongly aerated.  \tLevels from air-equilibrium up to approximately          2x the air-equilibrium figure may be seen commonly, depending on the age          of the setup and the surface agitation. Immature tanks (less than six          months old) rarely carry the microbial load of older tanks.<\/p>\n<p>#4: Java Moss and Java Fern are two of the best clogging devices in my          experience.<\/p>\n<p>#5: Such treatments include chlorine, chloramines, and short-life buffers.          Air equilibrium by release of higher concentrations of dissolved gases          is another positive benefit of local aging or tempering of water prior          to system addition.<\/p>\n<p>#6: \u00e2\u20ac\u0153Frequently\u00e2\u20ac\u009d is in the mind or judgment of the operator.          I learned in my SW days that daily rinses of overflow prefilters made          a huge difference in end pollution (nitrate, organics, whatever). I do          not rinse FW prefilters and internal mechanical-only filters daily, but          if I did so, I could reduce my water partials significantly. Weekly rinses          are my aim, even if it is not always accomplished. Every ten days for          the tank-internal mechanical filters is enough to keep the tanks and me          happy. Some of the constant level siphons used in system circulation and          a few of the simple siphons also involve sponge filtration as livestock          barriers. For me, those require weekly rinsing at the minimum. When I          operated the system at higher flow rates, duplicate filers were required,          along with twice weekly rinsing.<\/p>\n<p>#7: Such a \u00e2\u20ac\u0153setbacks\u00e2\u20ac\u009d could be a major pruning with vacuuming          and replanting. Or a major change in stocking levels could be another.<\/p>\n<p>#8: Bioload is based on the entire system, not on the individual tank.          In a stand-alone 15-gallon tank you would hesitate to a new dozen neon          tetras to an existing dozen \u00e2\u20ac\u201c the biofilters could need some catch-up          time. In a central system or circulating range, the bioload is based on          the total system volume, and that is likely to be some multiple of any          given tank volume. You would not hesitate to double the stock of one small          schooling fish group among many fish in a 300-gallon tank would you?<\/p>\n<p>#9: My current system has 19.5 square feet of surface in the main loop,          plus 6 in the secondary loop, for a total of 25.5 square feet of nominal          surface. The filter and sump is 5.5 square feet nominal. Obviously in          power-off situations, the higher drain-down levels than under positive          flow will be magnified in the reduced-area filter and sump. In my setup,          that translates into an increase in the level of the sump-filter combo          four and a half times the drop in the tank levels between operational          and power-down. If your sump cannot hold that much, you get a nice thin          layer of water on the floor.<\/p>\n<p>#10: The unfiltered outflow from the daphnia tank fed into the sump,          which was stocked with Singapore shrimp. Those were the best filter-feeding          shrimp I have kept. They bred regularly, but were not reared due to the          hatchling\u00e2\u20ac\u2122s need for brackish to marine conditions.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>At the August 2007 meeting, Robert T. Ricketts talked about the pros and cons of running planted tanks in a multi-tank system. Robert has written up his talk in his notes below&#8230; In principle these systems are doing the same job as the use of a sump on a display tank to house some, most, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":54,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-82","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/pages\/82","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/comments?post=82"}],"version-history":[{"count":1,"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/pages\/82\/revisions"}],"predecessor-version":[{"id":83,"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/pages\/82\/revisions\/83"}],"up":[{"embeddable":true,"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/pages\/54"}],"wp:attachment":[{"href":"https:\/\/gwapa.org\/wordpress\/wp-json\/wp\/v2\/media?parent=82"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}